SIEMENS
SOLAR MODULES
The Siemanes Solar Modules of
the series SM, SP and SR possess a Warranty 25 years old with
relationship to the fall of potency capacity in more than 20% of the
specified minimum potency, and of 10 years for a fall of more than 10%.
The modules of the series ST possesses 5 year-old warranty for a fall of
more than 10%.
The modules of the series SM,
SP and SR use cells monocristalinas. The series ST uses technology of
fine film (Thin Film) of CIS (Copper Indium Diselenide).
SERIES
SM
|
Model
|
a |

SM46
|

SM20
|
| Code old Siemens |
a |
M65 |
M20 |
|
Maximum potency |
W |
46 |
20 |
| Minimum potency |
W |
41 |
18 |
| Current @ Maximum Potency |
A |
3.15 |
1,38 |
| Tension @ Maximum Potency |
V |
14,6 |
14,5 |
| Short circuit current |
A |
3,35 |
1,60 |
| Tension in open circuit |
V |
18,0 |
18,0 |
| Configuration of Cells |
a |
30xM |
30xM/2 |
| Capacity of daily load * |
Ah/dia |
15,8 |
6,9 |
| Use of recommended regulator |
a |
a |
a |
| Connection type |
a |
2x Procharger
S |
cabos |
| Length |
mm |
1083 |
567 |
| Width |
mm |
329 |
329 |
| Thickness |
mm |
34 |
35 |
| Weight |
kg |
4,6 |
2,5 |
| Code |
a |
10100 |
10322 |
SERIES
SP
|
Model
|
a |

SP75 |

SP70 |

SP65 |
| Code old Siemens |
a
|
PC4/Pro4 JF |
- |
- |
|
Maximum potency |
W |
75 |
70 |
65 |
| Minimum potency |
W |
70 |
65 |
60 |
| Current @ Maximum Potency |
A |
4,40 |
4,25 |
3,95 |
| Tension @ Maximum Potency |
V |
17,0 |
16,5 |
16,5 |
| Short circuit current |
A |
4,80 |
4,70 |
4,5 |
| Tension in open circuit |
V |
21,7 |
21,4 |
21,4 |
| Configuration of Cells |
a |
36xP |
36xP |
36Xp |
| Capacity of daily load * |
Ah/dia |
22,0 |
21,0 |
19,8 |
| Use of recommended regulator |
a |
sim |
sim |
sim |
| Connection type |
a |
Procharger
CR |
Procharger
CR |
Procharger
CR |
| Length |
mm |
1200 |
1200 |
1200 |
| Width |
mm |
527 |
527 |
527 |
| Thickness |
mm |
34 |
34 |
34 |
| Weight |
kg |
7,6 |
7,6 |
7,6 |
| Code |
a |
10102 |
10461 |
11495 |
SERIES
CONTINUE SP
|
Model
|
a |

SP36 |

SP18 |

SP10 |
| Code old Siemens |
a |
PC2/Pro2 JF |
PC1/Pro1 JF |
- |
|
Maximum potency |
W |
36 |
18 |
10,5 |
| Minimum potency |
W |
32 |
16 |
10 |
| Current @ Maximum Potency |
A |
2.1 |
1,10 |
0,60 |
| Tension @ Maximum Potency |
V |
17,0 |
17,0 |
17,4 |
| Short circuit current |
A |
2,40 |
1,20 |
0,67 |
| Tension in open circuit |
V |
21,7 |
21,7 |
21,3 |
| Configuration of Cells |
a |
36xP/2 |
36xP/4 |
36xP/6 |
| Capacity of daily load * |
Ah/dia |
10,5 |
5,5 |
3,0 |
| Use of recommended regulator |
a |
sim |
sim |
sim |
| Connection type |
a |
Procharger
CR |
Procharger
CR |
Cabos |
| Length |
mm |
633 |
633 |
438 |
| Width |
mm |
527 |
275 |
310 |
| Thickness |
mm |
34 |
34 |
20 |
| Weight |
kg |
4,3 |
2,7 |
1,0 |
| Code |
a |
10281 |
10354 |
13721 |
SERIES
SR
|
Model
|
a |

SR100 |

SR90 |

SR50 |
| Code old Siemens |
a |
- |
- |
- |
|
Maximum potency |
W |
100 |
90 |
50 |
| Minimum potency |
W |
90 |
80 |
45 |
| Current @ Maximum Potency |
A |
5,9 |
5,4 |
2,95 |
| Tension @ Maximum Potency |
V |
17,0 |
17,0 |
17,0 |
| Short circuit current |
A |
6,5 |
6,1 |
3,2 |
| Tension in open circuit |
V |
21,6 |
21,6 |
21,6 |
| Configuration of Cells |
a |
36xR |
36xR |
36xR/2 |
| Capacity of daily load * |
Ah/dia |
29,5 |
27,0 |
14,7 |
| Use of recommended regulator |
a |
sim |
sim |
sim |
| Connection type |
a |
Procharger
CR |
Procharger
CR |
Procharger
CR |
| Length |
mm |
1498 |
1498 |
783 |
| Width |
mm |
594 |
594 |
594 |
| Thickness |
mm |
40 |
40 |
34 |
| Weight |
kg |
14 |
14 |
5,9 |
| Code |
a |
10996 |
10995 |
11496 |
SERIES
ST
|
Model
|
a |

ST10 |

ST5 |
| Code old Siemens |
a |
- |
- |
|
Maximum potency |
W |
10 |
5 |
| Minimum potency |
W |
9 |
4,5 |
| Current @ Maximum Potency |
A |
0,53 |
0,27 |
| Tension @ Maximum Potency |
V |
18,8 |
18,8 |
| Short circuit current |
A |
0,61 |
0,31 |
| Tension in open circuit |
V |
25,0 |
25,0 |
| Configuration of Cells |
a |
- |
a |
| Capacity of daily load * |
Ah/dia |
2,65 |
1,35 |
| Use of recommended regulator |
a |
a |
a |
| Connection type |
a |
cabos |
cabos |
| Length |
mm |
387 |
328 |
| Width |
mm |
328 |
206 |
| Thickness |
mm |
36 |
36 |
| Weight |
kg |
2,4 |
1,4 |
| Code |
a |
13710 |
13709 |
* being considered a heatstroke of 5
equivalent hours of pick
CONTROLLERS
OF LOAD: Responsible for the
managing of the whole system this equipment is fundamental to avoid
overloads or the discharge in excess of the battery enlarging its useful
life, this equipment has fuse that serves as protection for the whole
system..
ATTENTION:
Electronic Fuse will separate automatically, if there are a short one or
a super load in the system. in case that happens, turn off the lamps or
apparels and substitute the burned fuse
| |
1 |
2 |
3 |
4 |
5 |
| Capacity
(A) |
6 |
8 |
12 |
20 |
30 |
| Tension(V) |
12/24 |
12/24 |
12/24 |
12/24 |
12/24 |
| LVD(*) |
S |
S |
S |
S |
S |
| (*)
LVD (Low Voltage Disconnect -protection
of battery discharge |
INVESTORS
OF CURRENT
This equipment is a
necessary accessory to call equipments whose necessary tension is 110 /
220 Volts. The same should be directly linked to the bank of batteries.
The Investor converts the energy of the battery (12v) in alternate
current 110v - 60hz, it cannot him then to tie an or more appliances
(Radio, Tv, Computers, Cd-Player, Tools and etc.) In the total of until
the capacity (potency) of the investor. (An investor of 300w is
generally enough for a residence without refrigerator). In case of
larger need it consults us regarding investors with potency of up to
4750 W. When not used the investor should be turned off through the
button On/Off, being avoided like this, the loss of load of the
batérias. Important: Never tie directly the equipments in the batteries.
*Para to tie a colored TV of 14 inches 110 / 220 V is necessary an
investor of 300 Watts of potency. Important: Never tie directly the
equipments of 110/220 V in the batteries of 12v.
INVESTORS STATPOWER
|
Model
|
a |

PortaWattz 140 |

PortaWattz 300 |
|
Maker |
a |
Statpower |
Statpower |
|
Entrance tension |
V
(DC) |
10
a 15 |
10
a 15 |
| Exit tension |
V
(AC) |
115
± 5% |
115
± 5% |
| Exit frequency |
Hz |
60 |
60 |
| Continuous potency |
W |
140 |
300 |
| Potency 5min |
W |
a |
a |
| Potency of I supply |
W |
200 |
500 |
|
It forms of wave of
exit |
a |
senóide
modified |
senóide
modified |
| Efficiency @ stocking
potency |
% |
90 |
90 |
| Consumption without load |
A |
<0,06 |
<0,1 |
| Bat alarm. discharged |
V |
10,6 |
10,6 |
| Court tension |
V |
10 |
10 |
| Battery intern's loader |
a |
no |
no |
| Takings of Exit |
a |
1 |
2 |
| Dimensions |
mm |
119x119x41 |
152x119x46 |
| Weight |
kg |
0,6 |
0,9 |
| Code |
a |
12274 |
12276 |
INVESTORS
STATPOWER
CONTINUE
|
Model
|
a |

PortaWattz 600 |

PortaWattz 1000 |
|
Maker |
|
Statpower |
Statpower |
|
Entrance tension |
V
(DC) |
10 a 15 |
10 a 15 |
| Exit tension |
V (AC) |
115 ± 5% |
115 ± 5% |
| Exit frequency |
Hz |
60 |
60 |
| Continuous potency |
W |
600 |
800 |
| Potency 5min |
W |
600 |
1000 |
| Potency of I supply |
W |
1200 |
2000 |
|
It forms of wave of
exit |
a |
senóide
modified |
senóide
modified |
| Efficiency @ stocking
potency |
% |
90 |
90 |
| Consumption without load |
A |
<0,3 |
<0,3 |
| Bat alarm. discharged |
V |
10,6 |
10,6 |
| Court tension |
V |
10 |
10 |
| Battery intern's loader |
a |
no |
no |
| Takings of Exit |
a |
3 |
3 |
| Dimensions |
mm |
280x160x65 |
260x240x83 |
| Weight |
kg |
2 |
2,4 |
| Code |
a |
12277 |
12278 |
INVESTORS STATPOWER
CONTINUE
|
Model
|
a |

PortaWattz 1750 |
|
Maker |
a |
Statpower |
|
Entrance tension |
V
(DC) |
10 a 15 |
| Exit tension |
V (AC) |
115 ± 5% |
| Exit frequency |
Hz |
60 |
| Continuous potency |
W |
1500 |
| Potency 5min |
W |
1750 |
| Potency of I supply |
W |
3000 |
|
It forms of wave of
exit |
a |
senóide modificada |
| Efficiency @ stocking
potency |
% |
90 |
| Consumption without load |
A |
<0,6 |
| Bat alarm. discharged |
V |
10,6 |
| Court tension |
V |
10 |
| Battery intern's loader |
a |
năo |
| Takings of Exit |
a |
3 |
| Dimensions |
mm |
413x240x83 |
| Weight |
kg |
3,7 |
| Code |
a |
12279 |
|
BANK OF BATTERIES
|

|
Responsible for the storage of the energy
captured during the day. The use of stamped batteries is recommended (freedom)
that don't need of water replacement for the periodic maintenance. The
Bank of Batteries should have its dimensionamento calculated in
agreement with the data to proceed
To calculate the size correctly in (Ah) of
the bank of batteries of its system, come back for the item AS
DIMENSIONAR and observe the step number 7. Any doubt enters
in contact with us, we are always ready to serve.
|
LAMPS
/ LAMPS |
 |
We recommended the use of compact
fluorescent lamps of 9W and 11W 12 V. The same ones they possess great
brightness and they are quite economic. Offering like this larger
autonomy to its system, these special lamps of 12 V correspond to lamps
of 60 candles, with the advantage that you/they last much more than a
common lamp (up to 10.000 hours). it Avoids to install lamps in places
with leaks or infiltrations. For a larger useful life of the same ones
it avoids to call and to turn off simultaneously. This noxious practice
damages and it burns the lamps ACCESSORIES
|
|